Product Description
Technical specifications
Power supply | 12 - 24 VDC |
Max. sinking control voltage | -20 / +20 VDC |
Max. sourcing control voltage | 0 - 11 VDC |
Accuracy | <3% FS |
Max. sinking current | 2 mA |
Max. sourcing current | 7 mA |
Digital temperature sensor range (sensor must be ordered separately) |
-25°C~+80°C |
Operation temperature | -10° ~ +40°C |
Distance | up to 30 m indoors (depending on building materials) |
Dimensions (WxHxD) | 41.8 x 36.8 x 15.4 mm |
(packaging) | (79 x 52 x 22) |
Weight (including packaging) | 28 g (34 g) |
Electricity consumption | 0.5 W |
Supported Z-Wave Frequencies
ORDERING CODE | FREQUENCY |
ZMNHBD1 | 868.42 MHz |
ZMNHBD2 | 921.42 MHz |
ZMNHBD3 | 908.42 MHz |
ZMNHBD4 | 869 MHz |
ZMNHBD5 | 916 MHz |
ZMNHBD8 | 865.2 MHz |
Configuration parameters
Available configuration parameters (data type is 1 Byte DEC):
- default value 0
- 0 - mono-stable switch type (push button) – button quick press turns between previous set dimmer value and zero)
- 1 - Bi-stable switch type
- 2 - Potentiometer (Flush Dimmer 0-10V is using set value the last received from potentiometer or from Z-Wave controller)
- 3 - 0-10V Temperature sensor (regulated output)
- 4 - 0-10V Illumination sensor (regulated output)
- 5 - 0-10V General propose sensor (regulated output)

Parameter no. 11 - Automatic turning off output after set time
Available configuration parameters (data type is 2 Byte DEC):
- default value 0
- 0 - Auto OFF disabled
- 1 – 32536 = 1 second – 32536 seconds Auto OFF enabled with define time, step is 1 second.

Parameter no. 12 - Automatic turning on output after set time
Available configuration parameters (data type is 2 Byte DEC):
- Default value 0
- 0 - Auto ON disabled
- 1 – 32535 = 1 second – 32535 seconds Auto ON enabled with define time, step is 1 second.

Parameter no. 21 – Enable/Disable Double click function
If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. Available configuration parameters (data type is 1 Byte DEC):
- Default value 0
- 0 – double click disabled
- 1 – double click enabled

Parameter no. 30 - Saving the state of the device after a power failure
Available configuration parameters (data type is 1 Byte DEC):
- default value 0
- 0 – Flush Dimmer 0-10V device saves its state before power failure (it returns to the last position saved before a power failure)
- 1 – Flush Dimmer 0-10V device does not save the state after a power failure, it returns to "off" position.
Parameter no. 60 – Minimum dimming value
Available configuration parameters (data type is 1 Byte DEC):
- Default value 1 = 1 % (minimum dimming value)
- 1- 98 = 1% – 98 %, step is 1 %. Minimum dimming values is set by entered value.
Note: The minimum level may not be higher than the maximum level! 1 % min. dimming value is defined by Z-Wave multilevel device class.
Parameter no. 61 – Maximum dimming value
Available configuration parameters (data type is 1 Byte DEC):
- Default value 99 = 99 % (maximum dimming value)
- 2- 99 = 2 % – 99 %, step is 1 %. Maximum dimming values is set by entered value.
Note: The maximum level may not be lower than the minimum level! 99 % max. dimming value is defined by Z-Wave multilevel device class.

Parameter no. 65 – Dimming time (soft on/of)
Set value means time of moving the Flush Dimmer 0-10V between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet). Available configuration parameters (data type is 2 Byte DEC):
- Default value 100 = 1 s
- 50 - 255 = 500 mseconds – 2550 mseconds (2,55 s), step is 10 mseconds

Parameter no. 66 – Dimming time when key pressed
Time of moving the Flush Dimmer 0-10V between min. and max dimming values by continues hold of push button or associated device. Available configuration parameters (data type is 2 Byte DEC):
- Default value 3 = 3 s
- 1 - 255 = 1 second – 255 seconds
Electrical diagram

+ | +VDC (12-24 VDC) |
- | GND |
AO | Analog Output 0-10VDC |
I1 | Input for push button/switch/potentiometer or 0-10V |
TS | Terminal for digital temperature sensor (only for Flush Dimmer 0-10V device compatible digital temperature sensor, which must be ordered separately). |
S | Service button (used to add or remove device from the Z-Wave network) |