QUBINO 1 Relay (single switch)
$94.17
Stock: Available
Product Code: QUBINO1Relaysingle-switch
Flush 1 Relay The smart way to control your lights
Qubino Flush 1 Relay cares about home safety.
Prevent burglars from breaking into your home. Simulate your presence at home, by turning your lights on/off when you’re out.
Control the safety of your home with a single tap.
Product Description
Control your lights remotely
With Qubino smart home solutions you can check if your lights are on or off and control them using your smartphone.


Quick and Easy installation
1. Install our Qubino Flush 1 Relay behind the wall light switch;
2. Configure it through your Z-Wave gateway;
3. Control your lights using your smartphone.
Technical specifications
Power supply | 110 - 230 VAC ±10% 50/60Hz, (24-30 VDC) |
Rated load current of AC output (resistive load)* | 1 X 10A / 230 VAC |
Rated load current of DC output (resistive load) | 1 X 10A / 30 VDC |
Output circuit power of AC output (resistive load) | 2300 W (230 VAC) |
Output circuit power of DC output (resistive load) | 240 W (24 VDC) |
Power measurement accuracy | P = 5–50 W, +/-3 W P > 50 W, +/-3% |
Digital temperature sensor range (sensor must be ordered separately) |
-25°C~+80°C |
Operation temperature | -10° ~ +40°C |
Distance | up to 30 m indoors |
Dimensions (WxHxD) | 41.8 x 36.8 x 15.4 mm |
(packaging) | (79x52x22 mm) |
Weight (including packaging) | 28 g (34 g) |
Electricity consumption | 0.4 W |
For installation in boxes | Ø ≥ 60 mm or 2M, depth ≥ 60 mm |
Switching | Relay |
* In the case of loads other than resistive, pay attention to the value of cosφ and if necessary use a load lower than the rated load. Max current for cosφ = 0.4 is 3 A at 250 VAC, 3 A at 24 VDC L/R = 7 ms.
Supported Z-Wave Frequencies
ORDERING CODE | FREQUENCY |
ZMNHAD1 | 868.42 MHz |
ZMNHAD2 | 921.42 MHz |
ZMNHAD3 | 908.42 MHz |
ZMNHAD4 | 869 MHz |
ZMNHAD5 | 916 MHz |
ZMNHAD8 | 865.2 MHz |
Configuration Parameters

Parameter no. 1 & no. 2 – Input I1 & Input I2 switch type
Available configuration parameters (data type is 1 Byte DEC):
- default value 1
- 0 - mono-stable switch type (push button)
- 1 - bi-stable switch type

Parameter no. 2 & no. 3 – Input I2 & input I3 contact type
To Input I2 you can connect push button for scenes or any kind of binary sensor, like open door-window sensor.
Available configuration parameters (data type is 1 Byte DEC):
- default value 0
- 0 - NO (normally open) input type
- 1 - NC (normally close) input type

Parameter no. 11 - Automatic turning off output after set time
TVs, Hi-Fi systems and other home appliances have already integrated automatic turn off functionality, this device also offers this functionality. Automatic turning off function allows energy saving, without doing scenes on Z-Wave controller.
This function, for example also allows automatic re-locking door after defined time.
When Relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the device receive ON command regardless from where it comes (push button, associated device, controller,..).
Available configuration parameters (data type is 2 Byte DEC):
- Default value 0
- 0 - Auto OFF disabled
- 1 – 32535 = 1 second (0,01 s) – 32535 seconds (325,35 s) Auto OFF enabled with define time, step is 1 s or 10 ms according to parameter nr. 15

Parameter no. 12 - Automatic turning on output after set time
When Relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the device receives OFF command regardless from where it comes (push button, associated device, controller, etc.).
Available configuration parameters (data type is 2 Byte DEC):
- Default value 0
- 0 - Auto ON disabled
- 1 – 32535 = 1 second (0,01 s) – 32536 seconds (325,35 s) Auto ON enabled with define time, step is 1 s or 10 ms according to parameter nr. 15

Parameter no. 21 – Enable/Disable Double click function
If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. Available configuration parameters (data type is 1 Byte DEC):
- Default value 0
- 0 – double click disabled
- 1 – double click enabled

Parameter no. 15 - Automatic turning off / on seconds or milliseconds selection
Available configuration parameters (data type is 1 Byte DEC):
- Default value 0
- 0 – seconds selected
- 1 – milliseconds selected
NOTE: Parameter is the same for turning OFF or ON.

Parameter no. 30 - Saving the state of the relays Q1 and Q2 after a power failure
Available configuration parameters (data type is 1 Byte DEC):
- default value 0
- 0 – Flush 2 Relay device saves its state before power failure (it returns to the last position saved before a power failure)
- 1 - Flush 2 Relay device does not save the state after a power failure, it returns to "off" position.

Parameter no. 40 – Power reporting in Watts on power change
Set value means percentage, set value from 0 - 100 = 0 % - 100 %. Available configuration parameters (data type is 1 Byte DEC):
- default value 10 = 10 %
- 0 – Reporting Disabled
- 1 – 100 = 1 % - 100 % reporting enabled
Power report is sent (pushed) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1 %.
NOTE: If power changed is less than 1 W, the report is not sent (pushed), independent of percentage set.

Parameter no. 42 – Power reporting in Watts by time interval
Set value means time interval (0 – 32535) in seconds, when power report is sent. Available configuration parameters (data type is 2 Byte DEC):
- default value 300 = 300 s
- 0 – Reporting Disabled
- 1 – 32535 = 1 second – 32535 seconds.
Reporting enabled. Power report is sent with time interval set by entered value.

Parameter no. 63 – Output Switch selection
Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC):
- default value 0
- 0 - When system is turned off the output is 0V (NC).
- 1 - When system is turned off the output is 230V or 24V (NO).


Parameter no. 100 & no. 101 – Enable / Disable Endpoints I2 & I3 or select Notification Type and Event
Enabling I2 & I3 means that Endpoint (I2 & I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC):
Endpoint device type selection:
- notification sensor (1 - 6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
- default value 0
- 1- Home Security; Motion Detection, unknown loc.
- 2 – Carbon Monoxide; Carbon Monoxide detected, unknown location.
- 3 – Carbon Dioxide; Carbon Dioxide detected, unknown location.
- 4 – Water Alarm; Water Leak detected, unknown loc.
- 5 – Heat Alarm; Overheat detected, unknown loc.
- 6 - Smoke Alarm; Smoke detected, unknown loc.
- 0 – Endpoint, I2 & I3 disabled
- sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY,
SPECIFIC_TYPE_NOT_USED
- 9 – Sensor binary
NOTE 1: After parameter change, first exclude device (without setting parameters to default value) then wait at least 30 s and then re-include the device!
NOTE 2: When the parameter is set to value 9 the notifications are sent to Home Security.
Temperature Sensor Setting



Parameter no. 110 – Temperature sensor offset settings
If the temperature sensor is connected to the device, the temperature sensor widget is shown automatically in UI (user interface).
If the measured temperature with an additional temperature measuring device is different from the one measured by the connected digital temperature sensor, the temperature can be compensated by this parameter.
Available configuration parameters (data type is 2 Byte DEC):
- default value 32536
- 32536 – offset is 0.0 °C
- From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.

Parameter no. 120 – Digital temperature sensor reporting
If digital temperature sensor is connected, device reports measured temperature on temperature change defined by this parameter.
Available configuration para meters (data type is 1 Byte DEC):
- Default value 5 (Temperature is reported on 0.5 °C change)
- 0 – Reporting disabled
- 1- 127 = 0.1 °C – 12.7 °C, step is 0.1 °C
Electrical diagram

N | Neutral wire (+VDC) |
L | Live (line) wire (-VDC) |
Q↑ | Output for electrical device (load) no. 1 |
I3 | Input for switch /push button or sensor |
I2 | Input for switch /push button or sensor |
I1 | Input for switch /push button |
TS | Temperature sensor terminal |
S | Service button (used to add or remove device from the Z-Wave network) |
*Wago 221-413 splicing connectors for L and N connection must be used only when connected to 240 VAC.